ANNEX PUBLISHERS

Journal of Immunology and Infectious Diseases

ISSN: 2394-6512

Open Access
Research Article
Max Screen >>

Field Evaluation and Use of a Non Commercial Peptide Enzyme Immunoassay for Human Immunodeficiency Virus Serotyping in Abidjan (Ivory Coast)

Received Date: January 17, 2017 Accepted Date: June 14, 2017 Published Date: June 16, 2017

Copyright: © 2017 Inwoley A. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Related article at Pubmed, Google Scholar

Abstract

In West Africa, where Human Immunodeficiency Viruses 1 and 2 (HIV-1 and HIV-2) co-circulate, serological assays allowing the reliable serotyping of HIV infection are needed. This study evaluated the performance and described the experience in using a non-commercial peptide-based enzyme immunoassay (PBEIA) in a context of resource-limited setting.

The PBEIA uses peptides representative of the immunodominant regions of the transmembrane glycoprotein and the surface glycoprotein (V3 loop) of both HIV-1 (gp41 and V3.1) and HIV-2 (gp36 and V3.2). The evaluation of this assay was carried out using: 510 serum samples including 200 from HIV-negative individuals and 310 from HIV-positive individuals (130 HIV-1,105 HIV-2 and 75 HIV with dual seroreactivity) based on results obtained and 145 other samples positive for HIV-2. Murex HIV-1.2.OTM, Vironostika HIV Uni-Form II plus OTM and western blot tests were used as reference gold standard assays.

The sensitivity of gp41, gp36, V3.1 and V3.2 was 100% (95% confidence intervals [CI]: 100-100%), 96.6% (95% CI: 94.5-97.9%), 96.9% (95% CI: 95.4-98.4%), and 60% (95% CI: 50.6-69.4%), respectively. The specificity was 100% for gp41, V3.1 and V3.2 (95% CI: 100-100%) and 97.7% (95% CI: 94.4-99.9%) for gp36. The discriminatory power of the PBEIA was very good with a Kappa value equal to 0.94. Operationally, PBEIA was convenient and presented a very low production cost, when compared to immunoblot testing. PBEIA was routinely used to analyze 15,734 samples from 2006 to 2013 and led to 198 (1.2%) false negative results. Among the 759 samples which tested HIV-1+2 at dilution 1/100, only 334 (44%) were confirmed HIV-1+2 at dilution 1/500, while 388 (51.1%) and 37 (4.9%) were reclassified as HIV-1 and HIV-2 mono-infections, respectively.

In conclusion, the excellent performance of PBEIA associated with its low cost confirmed that this assay can be used routinely by reference laboratories. This technique is also useful to reclassify all samples that are identified as HIV dually reactive with discriminatory rapid tests in peripheral laboratories.

Keywords: HIV; ELISA; serotyping; Ivory Coast

Introduction

HIV infection has become a global epidemic and a major public health problem worldwide. In 2015, among a total of 36.7 million [34.0-39.8] people living with HIV (PLHIV), 6.5 million [5.3-7.8] were in Western and Central Africa [1]. In West Africa, Ivory Coast displayed the highest prevalence rate which was 3.2% among subjects aged 15-49 [2].

The fight against this pandemic needs simultaneous use of effective preventive action and wider access to treatment. However, in the absence of vaccine, fighting activities focus firstly on prevention through awareness of infection status and secondly on a better therapeutic management of infected persons. Given its importance in struggling against AIDS, biological diagnosis of HIV infection is importance and is based on the detection of antibodies in adults and children over 18 months. The “conventional” strategy associates antibody screening by one or more enzyme-linked immunosorbent assays (ELISA), and a confirmation of positive results with Western blot. This strategy is not always feasible in developing countries for many reasons. Indeed, this strategy requires appropriate laboratory equipment, qualified staff, and is characterized by a high cost. Thus, the World Health Organization (WHO) recommends to use simpler and cheaper alternative strategies such as rapid diagnostic tests (RDTs) for countries with limited resources [3]. There is a proliferation of commercial HIV screening tools, but according to the WHO, the genetic diversity of HIV requires the evaluation of any screening test prior to use in a given area [4]. In Ivory Coast, the predominant subtype of HIV-1 is the recombinant form CRF02_AG [5,6], but HIV-2 also circulates as in other countries of West Africa [7]. Therefore, screening strategies must also include a discriminating test in order to determine the HIV serotype in patients, mainly because of the natural resistance of HIV-2 to non-nucleoside inhibitors of reverse transcriptase [8,9].

RDTs able to discriminate between HIV-1- or HIV-2- seroreactivity have been developed. Although several studies have described the good performance of tests and algorithms used in West Africa for HIV diagnosis the limited performances of discriminating rapid tests were noted [10-13]. A large-scale implementation of more efficient commercial assays is challenging in countries with limited resources.

During the past two decades, non-commercial ELISA’s assays have been developed for HIV serotyping dedicated to epidemiological studies conducted in developed countries. For instance, Barin, et al.. used a non-commercial ELISA based on peptides representative of immunodominant regions of the HIV glycoproteins (peptide-based enzyme immunoassay, [PBEIA]) to achieve the monitoring of HIV strains circulating in France [14-16].

The objectives of this study were to transfer and evaluate the performance of this tool in Ivory Coast and to describe its routine use during 8 years in our laboratory.

Materials and Methods
Assessment Panels

PBEIA evaluation was conducted from June 2004 to November 2005 on two different sera panels from the biobank of the Centre for Diagnostic and Research for AIDS and Other Infectious Diseases (CeDReS) located at the teaching hospital of Treichville in Abidjan, Ivory Coast.

Sera of Panel 1 were collected from pregnant women attending in six urban community based antenatal clinics in the city of Abidjan during the ANRS 1201/1202 DITRAME PLUS project from March 2001 to April 2003. This was an open cohort conducted in Abidjan whose objective was to evaluate the efficacy of antiretroviral short regimens (AZT + NVP and AZT + 3TC + NVP) in preventing mother to child transmission of HIV (PMTCT) [17]. This panel consisted of 510 samples including 200 negative and 310 positive (130 HIV-1, 105 HIV-2 and 75 HIV-1+2 dual reactivity), according to WB results.

Panel 2 was obtained from patients who were enrolled in three HIV care centers of Abidjan: department of pneumology/teaching hospital of Treichville, Abidjan Integrated Center for Bio-Clinical Research (CIRBA) and Center for Care, Research and Training (CePReF). This panel contained 145 samples positive for HIV-2, according to ELISA and WB results. Samples were collected during a study dedicated to an evaluation rapid test for the health ministry from January to march 2007.

Ethical considerations

The ANRS 1201/1202 DITRAME PLUS study (for panel 1) and rapid test evaluation (for panel 2) were approved by the Ivorian ministry of health ethical committee and all participants gave their consent for HIV testing.

Description of the PBEIA

PBEIA is an indirect enzyme-linked immunosorbent assay adapted from that described by Barin and colleagues [15]. PBEIA used for HIV-1 synthetic peptides of the immunodominant region of gp41 (consensus sequence of all clades and consensus of clade D respectively, RVLAVERYLKDQQLLGIWGCSGKLICTTAV and RILAVESTLKDQQLLGIWGCSGRHICTTAV) and the V3 loop (named V3.1). For HIV-2, PBEIA used synthetic peptides of the immunodominant region of gp 36 (RVTAIEKYLKDQAQLNSWGCAFRQVGHTTV) and the V3 loop (V3.2, respectively). These peptides were produced by PolyPeptide Laboratories (France) and used as antigens of the solid phase to coat FALCON flexible plates (BD Biosciences. Belgium). The coating was made in our laboratory with these antigens at the concentration of 1 μg/ml (gp41 and gp36) or 2.5 μg/ml (V3.1 and V3.2) with overnight incubation at 37 °C. Then, after 3 washes with 150 μl of wash buffer (phosphate buffered saline with 0.5% Tween 20), wells are saturated with 200 μl of blocking buffer (phosphate buffered saline containing 2% fetal calf serum) (Sigma-Aldrich. USA) at 37 °C for 45 minutes, followed by three washes as above. After drying, plates are ready for use or can be wrapped in aluminum foil and stored at -20 °C for 6 weeks.

For serotyping, a 96-well plate is brought back to room temperature before use. Each sample and controls to be tested are diluted to 1/100 in a buffer (phosphate buffered saline containing 10% fetal calf serum and 0.005% tween 20). Only the samples retested were diluted to 1/500. One hundred microliters of each diluted sample are added to 4 wells of the plate allowing incubation with the 4 peptides (gp41, gp36, V3.1 and V3.2). In each plate, 3 negative controls, one HIV-1 positive control and one HIV-2 positive control are included. Thirty minutes after incubation at 18 °C, wells are subjected to 5 washes with 150 μl wash buffer each.

Thereafter, 100μl of 1/5000 dilution of conjugate: (F'(ab) 2) anti-human immunoglobulin G goat antibody coupled to peroxidase (Clinisciences. Strasbourg) are distributed in each well of the plate and incubated for 30 minutes at 18 °C. After 5 washes, revelation is done by adding 100 μl of Ortho-phenylenediamine hydrochloride Di-fast as substrate (Sigma-Aldrich. USA). After incubation in the dark for 15 minutes at 18 °C, reaction is stopped by adding 50 μl of 2N sulfuric acid per well. The optical density (OD) is measured at 490 nm with a reference filter at 630 nm within 30 minutes.

Reference tests

For panel 1, samples were screened by performing the Murex HIV-1.2.OTM (Abbott. Dartford. United Kingdom) and Vironostika HIV Uni-form II plus OTM (Organon Teknika, Boxtel, Netherlands). Then, HIV serotyping was done with the Pepti-LAV-1/2TM (BioRad Diagnostics, Marne-La Coquette, France). Any sample which gave a discordant result between the PBEIA and Pepti-lav1/2TM was analyzed further by Western Blot assays: New Lav blot I and New Lav blot IITM (BioRad Diagnostics, Marne-la-Coquette, France).

For panel 2, samples were screened with Vironostika HIV Uni-form II plus OTM assay and serotyped with New lav blot I and New lav blot IITM. In all cases, Western blot tests were interpreted according to the WHO criteria [4,18].

Experience of use

After its evaluation, PBEIA was used routinely at CeDReS between 2006 and 2013 for serotyping through the following algorithm. All samples were tested with Vironostika HIV Uni-Form II Ag/AbTM for screening. Positive samples were serotyped with the PBEIA. For negative results, samples were retested by both tests. In case of HIV dual reactivity by PBEIA, samples were retested at dilution 1/500.

Statistical analysis

Results obtained with panel 1 were used to calculate the negativity threshold value (NTV) and the positive threshold value (PTV) using the following formulas: (i) NTV = (average negOD) + 3 (standard deviation of negOD). (ii) PTV = (average posOD) + 3 (standard deviation of posOD).

For screening, sensitivity and specificity were calculated by comparing the PBEIA to non-discriminatory tests i.e. Murex HIV-1.2.OTM (Abbott. Dartford. United Kingdom) or Vironostika HIV Uni-form II plus OTM. For serotyping, sensitivity of each peptide was calculated for its ability to identify the right serotype. Similarly, specificity of each peptide was calculated for its ability to identify the correct serotype. Kappa concordance value was also calculated [19].

Results
Determination of threshold values

Figure 1a shows distribution of ODs obtained with PBEIA for 200 negative samples. NTV obtained for gp41, V3.1, V3.2 and gp36 peptides were respectively: 1.15; 1.26; 0.95 and 0.85. Given these values were close to 1, the NTV was set to 1 for all peptides.

Thus, all samples showing an OD of less than 1 were considered negative by PBEIA. Negative threshold value at dilution 1/500 was set at 0.5 by applying the same principle. We also determined the PTV by analyzing ODs of HIV serotype 1 samples on the one hand and those of HIV serotype 2 on the other hand. PTV was set to 2 at dilution 1/100 (Figure 1b and 1c). PTV was set to 1 for dilution 1/500.

Detection performance of each peptide used for HIV-1 and HIV-2 serotypes at NTV and PTV thresholds is shown in Table 1. On panel 1, according to the PTV, HIV-1 sensitivity of gp41 and V3.1 peptides was 100% (95% CI: 100-100%) and 96.9% (95% CI: 95.4-98.4%), respectively. For HIV-2, sensitivity of gp36 and V3.2 peptides was 96.2% (95% CI: 94.5-97.9%) and 60% (95% CI: 50.6-69.4%), respectively. Regarding specificity, at threshold value 2, specificity of gp41, V3.1 and V3.2 peptides was 100% (95% CI: 100-100%) whereas specificity of gp36 peptide was 97.7% (95% CI: 94.4 -99.9%). Thus, among four samples which were negative at threshold 2 with gp36, three ones with OD between 1 and 2 were positive with this peptide at 1/500 dilution because OD was more than 1. At threshold value 1, cross-reactivity was obtained with all peptides with a higher frequency for HIV-2 peptides. Any sample, for which a cross-reaction was suspected (OD between 1 and 2) with at least one of the peptides, was retested at dilution 1/500. At this dilution, samples that gave an OD lower than 0.5 (NTV of this dilution) were declared negative with this peptide.

All these results allowed us to define stringent criteria for the interpretation of the PBEIA:
(i) consider only transmembrane peptides gp41 (HIV-1) and gp36 (HIV-2);
(ii) samples giving an OD greater than 2 are considered positive for each peptide;
(iii) samples giving an OD between 1 and 2 for a peptide, as well as positive samples for both peptides at 1/100 dilution should be retested on the same plate at both dilutions 1/100 and 1/500;
(iv) samples tested at dilution 1/500 must be considered as positive if the OD is greater than 1.

Performance of the PBEIA

Regarding the screening performance of the PBEIA, we obtained one false negative out of 310 positive samples, leading to a sensitivity of 99.7% (95% CI: 99.2-100%) and a specificity of 100% (95% CI: 100-100%). This false negative sample was from an HIV-2 infected individual. The positive and negative predictive values were 100% (95% CI: 100-100%) and 99.5% (95% CI: 98.9-100%), respectively.

The discriminatory power of the PBEIA, in comparison with the Pepti-LAV 1/2TM assay, was high, with a Kappa value equal to 0.94 (Table 2). Serological profiles of the eleven samples which gave discordant results (3.6% discrepancy rate) are presented in Table 3. Of these, concordant results between PBEIA and Western blot assay were found for eight samples (72.7% concordance rate).

Results obtained on panel 2 are shown in Table 1. Using a threshold of 2, the sensitivity of gp36 peptide was 93.8% (95% CI 89.9-97.7 %). The 11 samples detected by gp41 which had OD values ranging between 1 and 2 at dilution 1/100 were retested at dilution1/500. At this dilution, all of them gave an OD less than 0.5 and therefore were declared negative with this peptide. However, the 9 samples detected by gp36 with an OD between 1 and 2 at dilution 1/100 and retested at dilution 1/500, gave an OD greater than 1 and then declared positive. In total, PBEIA showed 100% concordant results with Western Blot on panel 2.

Operationally, the PBEIA was convenient and had a lower cost price, when compared to Pepti-LAV-1/2TM (Table 4). However, its implementation can only be performed in laboratories with an adapted technical platform with at least an ELISA system.

User experience of the PBEIA

During the eight years of use, 15,734 samples were tested in first intention (at dilution 1/100) with 15,462 samples HIV-positive. 272 (1.7%) were tested negative and 760 tested positive for both HIV-1 and HIV-2 (HIV dual). After retesting the 272 samples negative by PBEIA, 74 were finally found positive including 50 with an OD lower than 2 for both peptides. It is noteworthy that when the OD ratio between the two peptides was greater than 5, the serotype is determined by the peptide having the highest OD. After retesting at dilution 1/500, the 760 samples which were dual positive at dilution 1/100, we obtained the following results: 388 HIV-1, 37 HIV-2 and 335 dual positives. Table 5 show distribution of ODs obtained respectively with gp41 and gp36 at the two dilutions, according to the final serotype found. For the 388 samples which tested HIV-1 positive with gp 41 peptide, only 7.7% (30/388) displayed an OD less than 1 at dilution 1/500. Similarly for the 37 samples which tested positive for HIV-2, 8% (3/37) presented an OD less than 1 at dilution 1/500 with gp 36 peptide. Overall, 1.3% negative results were obtained and the distribution of serotypes was 92.9%. 3.7% and 2.1% for HIV-1, HIV-2 and HIV-dual reactive respectively.

Discussion

In countries with limited resources, monitoring and diagnosis of HIV infection are major Public Health challenges [20]. Immunoassays including ELISA and RDTs are the most common and widespread diagnostic methods [21,22]. More efficient tests for serotyping such as Pepti-LAVTM and Western blot are very expensive for countries with limited resources [11,23]. Moreover, the production of some commercial discriminating ELISA formats by developed countries was stopped for lack of profitability. In this context, technical performance of a non-commercial ELISA (PBEIA) and its use for eight years were assessed. This study was conducted in West Africa with a local panel gathering all the conditions related to the variability of HIV strains in a given territory, especially in Africa. Negative samples showed optical densities greater than those previously obtained with negative sera in French population [14,15]. In fact, OD median value for each of the peptides was around 0.3 while Barin described ODs lower than 0.1 for negative controls [14,15]. This difference could be explained by: (i) the presence of other types of antibodies in the sera of subjects living in Africa, (ii) the living environment that promotes infection and therefore a greater stress for the immune system. We also recommend to include in each run of PBEIA positive and negative controls in order to validate the test: mean of negative control < 0.5 and positive control of each peptide > 2.

The performance analysis of each peptide revealed that synthetic peptides including gp41 and gp36 sequences were excellent candidates for the diagnosis of HIV infection. Barin et al has been reported that the discriminating power of the PBEIA could be slightly improved by combining immunodominant epitope of both gp41 and V3 [15]. Nevertheless, we obtained a low sensitivity of V3.1 peptide of HIV-1 and the two peptides of HIV-2 (gp36 and V3.2).In our study, V3 loop had no interest in determining the serotype of positive samples which finally took into account only the results of transmembrane peptides gp41 and gp36. Recently, Tiwari et al. developed a new antigenic cocktail including the 32 amino-acids heterovalent and oligomeric peptides “V3-I” in combination with gp41, gp36 and rp24. This increased the sensitivity and the specificity of an indirect ELISA assay developed for detecting anti HIV-1 and HIV-2 antibodies, thereby eliminating non-specific cross-reactivity. Moreover, a cross-reaction was observed with gp36 for two HIV-1 positive samples [24,25]. These cross-reactions are mitigated when the samples were diluted at 1/500 instead of 1/100. The low sensitivity (96.2 %) of gp36 was comparable to those reported with commercial discriminating ELISA kits whose production was discontinued [23,26,27]. This difficulty in detecting HIV-2 could be due to low HIV-2 viral loads, a characteristic of the HIV-2 natural infection, or could be due to the lack of detection of some subtypes of HIV-2. Indeed, HIV-2 variants of subtypes B are common in Côte d’Ivoire and we could have missed amplification our molecular technique [28,29]. The reduced sensitivity of the PBEIA may also be caused by improper selection of antigen and/or reduction of HIV-2 antibody levels in patients [30-32]. Marcellino increased to 100% the sensitivity an HIV-2 ELISA by using two new recombinant proteins, rgp36 and rpc2-C3 from HIV-2 primary reference isolate ALI [33-35]. These data were consistent with previous studies showing that gp36 recombinant proteins derived from HIV-2 strains of several laboratories are highly immunogenic [35-37]. It appears that routine use of PBEIA in our context, could disregard these V3 peptides. Thus, a ready-to-use ELISA plate could allow testing 48 samples instead of 24, and therefore reducing the unit price of the test.

Performance analysis of gp41 and gp36 peptides confirms the good sensitivity and specificity observed with the PBEIA. These results were similar to those obtained by Simon F and colleagues who found 98% specificity for an indirect ELISA developed from synthetic peptides gp41/gp36 and V3 of 4 lentivirus lines [38]. Although the sensitivity of PBEIA does not reach 100%, our data show that its good specificity makes it useful in a serial algorithm as second test for serotyping. The very good agreement between PBEIA and Pepti-LAV-1/2TM shows that it is a good alternative to commercial assay. Many dual-reactive samples by western blot were not confirmed by PBEIA. These results were consistent with previous studies including that of Tchounga, et al. who reported poor discrimination of dually infected samples in cohort of HIV-2 infected patients from 3 West African countries (Ivory Coast. Mali. Burkina Faso) [11,12,39,40,41]. The choice of serotyping techniques for HIV infection should take into account not only the technical performance but also the operational characteristics and the cost of the test. For a laboratory with ELISA system and qualified staff, the use of PBEIA is a good alternative. Indeed, PBEIA is suitable for large series of samples. In addition, PBEIA presents lower price cost (about 1 USD). While, Pepti-LAV 1/2TM and NEW LAV BLOTTM were more expensive with 25 USD and 100 USD per test. However, the routine use for nearly a decade (since 2006) of PBEIA at our lab CeDReS can raise some challenges: (i) Have enough flexibility in a results interpretation despite existence of positive and negative threshold values. (ii) Necessity to have another discriminant assay as an alternative for samples tested negative with PBEIA but positive with non-discriminatory assays. (iii) Necessity to retest at both dilutions (1/100 and 1/500) all samples giving an HIV-dual result at dilution 1/100 in order to reduce cross-reactions.

Conclusion

The excellent performance associate with low price cost of PBEIA reinforced our routine use of this discriminating assay. It may be used in reference laboratories to retest all samples dually reactive with discriminating rapid tests in peripheral laboratories. It would reduce the rate of HIV dual and render the management of antiretroviral treatments more accurate.

4Centers for Disease Control and Prevention (U.S) World Health Organization, Regional Office for Africa (2006) Guidelines for Appropriate Evaluations of HIV Testing Technologies in Africa.
22 Delaney KP, Branson BM, Uniyal A, Phillips S, Candal D, et al. (2011) Evaluation of the Performance Characteristics of 6 Rapid HIV Antibody Tests. Clin Infect Dis 52: 257-63.
28 McDougal JS, Pilcher CD, Parekh BS, Gershy-Damet G, Branson BM, et al. (2005) Surveillance for HIV-1 incidence using tests for recent infection in resource-constrained countries. AIDS 19: S25-30.
31Ishikawa K, Fransen K, Ariyoshi K, Nkengasong JN, Janssens W, et al. (1998) Improved detection of HIV-2 proviral DNA in dually seroreactive individuals by PCR. AIDS Lond. Engl. 12: 1419-25.

JOURNAL OF PHARMACEUTICS & DRUG DEVELOPMENT

Tables at a glance
Table 1
Table 2
Table 3
Table 4
Table 5
Figures at a glance
Figure 1
Figure 1: Distribution of optical densities (y-axis) of peptides (x-axis) of HIV samples tested negative (a) HIV-1 positive (b) and HIV-2 positive (c) X :maximum, : median, :minimum
Panel 1
Panel 2
HIV-1 (N=130)
HIV-2 (N=105)

HIV-2 (N=145)

OD ≥ 2
1<OD<2

OD≤ 1

OD ≥ 2
1<OD<2

OD≤ 1

OD ≥ 2
1<OD<2

OD≤ 1

Gp 41
130
0
0
0
1
104
0
11

134

V 3.1
126
2
2
0
2
103
Gp 36
3
11
116
101
3
1
136
9

0

V 3.2
0
6
124
54
23
28
Table 1: Detection performance of different HIV peptides
K= 0.94

Pepti-LAV 1/2TM

HIV-1
HIV-2
HIV-1+HIV-2
Total
PBEIA
HIV-1
129
0
6

135

HIV-2
0
104
4

108

HIV-1+HIV-2
1
0
65

66

Total
130
104
75
309
Table 2: Agreement between the PBEIA and Pepti-LAV 1/2
Number
PBEIA
Pepti-LAV 1/2TM
New LAV BlotTM I/ II
11539
HIV-2
HIV-1+2
HIV-2
11648
HIV-2
HIV-1+2
HIV-2
11886
HIV-2
HIV-1+2
HIV-2
20274
HIV-1
HIV-1+2
HIV-1
20773
HIV-2
HIV-1+2
HIV-2
20994
HIV-1
HIV-1+2
HIV-1
30346
HIV-1
HIV-1+2
HIV-1
31753
HIV-1
HIV-1+2
HIV-1+2
32496
HIV-1+2
HIV-1
HIV-1
32940
HIV-1
HIV-1+2
HIV-1+2
70176
HIV-1
HIV-1+2
HIV-1
Table 3: Profile of the 11 discordant samples
KIT
PBEIA
Pepti-LAV 1/2TM
Sample volume
10µl
30µl
Dilution
1/100
1/100
Working Temperature
18 °C
Room Temperature
Duration of the Test
1h 30 mn
1h 45 mn
Reading Mode
Spectrophotometer 490/630 nm
Visual
Storing Temperature
-20°C
+2 à 8°C
Cost of Production
1 USD
25 USD
Table 4: Characteristics of PBEIA and Pepti-LAV 1/2TM assays
Serotypes
Dilution 1/100
gp41 Dilution 1/500
gp 36 Dilution 1/500
OD≤0.5
0.5<OD<1
1<OD<2
OD≥2
OD≤0.5
0.5<OD<1
1<OD<2
OD≥2
HIV1
OD≤0.5
0
0
0
0
6
0
0
0
0.5<OD<1
0
0
4
0
20
3
0
0
1<OD<2
1
15
34
5
252
49
0
0
OD≥2
0
14
74
241
36
22
0
0
HIV2
0.5<OD<1
1
1
0
0
0
0
0
0
1<OD<2
22
8
0
0
0
2
5
1
OD≥2
4
1
0
0
0
1
13
15
HIV1+2
OD≤0.5
0
0
0
0
0
0
1
0
0.5<OD<1
0
3
1
0
1
4
1
1
1<OD<2
1
16
37
8
3
38
61
10
OD≥2
0
4
48
216
1
13
109
91
Table 5: Comparison of optical densities for peptides gp41 and gp36 at dilutions 1/100 and 1/500 for retested HIV dual samples (n= 759)